Low Frequency Online UPS
VR
PRODUCT DESCRIPTION


Key Features:

1.Use advanced 6th generation DSP and full digital control technologies to realize higher system stability.

2.Output power factor is 0.9, carrying capacity than conventional UPS with 10% above, as users reduce investment cost.

3.Advanced distributed active parallel technology can realize parallel operation of 6PCS UPS units without the need of centralized bypass cabinet.

4.6-inch extra large LCD that can display 12 language (Chinese ,English,Russian,Spanish,French and so on).

5.Extra wide input voltage and frequency range make it adapt to severe power grid environment.

6.Intelligent battery management maintains battery automatically to prolong the battery life.

7.Standard input/output filter improves the system EMC performance.

8.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.

9.Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe environment.

Parameter


ModelGP9315C 10-120KVA
Rectifier Type6p12p6p12p6p12p6p12p6p12p12P12P12P
Rated Nominal10KVA/9KW20KVA/18KW30KVA/27KW40KVA/36KW60KVA/54KW80KVA/72KW100KVA/90KW120KVA/108KW
Rated input voltage380/400/415VAC 3-phase 4-wire
Rated frequency50/60HZ
Input parameters 
Input voltage range±25%
Input frequency range45Hz~65Hz
Input soft start function0-100%   5-300settable
Input power factor>0.8
Input harmonic current (THDi)<20%
Bypass 
Bypass voltage range-20%~+15%
Bypass frequency range50/60HZ±10%
Output parameters 
Inverter output voltage220/230/240VAC 1-phase 3-wire
Voltage stability±1%(Steady status),±3%(Transient status)
Frequency50/60Hz
Mains power synchronization window±5%
Actually measured frequency accuracy (internal clock)50/60Hz±0.05Hz
Output power factor0.9(Output 90kW per 100kVA)
Transient response time<5ms
Inverter overload capabilityAt 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s
Short circuit current from inverter3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds
DC Voltage360/384/432/480VDC
Maximum Bypass capability1000% for 100ms
Phase Shift characteristicWith 100% balanced load<1°
With 100% imbalanced load <1°
Total harmonic Distortion(THDv)100% linear load<1%
100% non-linear load<3%
System efficiency (full load)Up to 94% (inverter efficiency is up to 98%)
Rectifier output parameters
Charger output voltage stability1%
DC ripple voltage≤1%
Operating environment 
Operating temperature range0~40°C
Storage temperature-25~70°C(Without battery)
Relative humidity0~95% No condensation
Maximum Operating Height≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m 
Noise (1m)58-68dB
Protection levelIP20
StandardSafety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
Physical Parameters
Weight(kg)980142012001750135020001600220021002750369063907390
Dimension(WxDxh)mm900*855*19001250*855*19001640*855*19001250*855*19001640*855*19002280*855*19002835*1000*19503955*1090*1950
Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

Contact Us

Take advantage of our unrivaled knowledge and experience, we offer you the best customization service.

CONTACT US

Feel free to communicate your ideas and ask lots of questions.

RECOMMENDED

Is a leading provider of power protection product and service solutions including UPS,SOLAR INVERTER,48VDC Power Supply,Outdoor battery banks.

Send your inquiry

Send your inquiry
Choose a different language
English
Türkçe
ภาษาไทย
Bahasa Melayu
Lëtzebuergesch
русский
Português
한국어
italiano
français
Español
Deutsch
العربية
Current language:English