Key Features:"Adopt full digital control technology.
=intelligent detection and monitoring function.
Digital control and static switch zero switching.
Input/output full isolation
DC UPS isolated with utility power completely.
Cubicle design with power standard
Multifunctional protection for overvoltage,low voltage,
Overcurrent,short circuit and so on.
Large-screen LCD monitor Chinese and Englishoperation interface.
Ultralong 256 event records,user-friendly analysis and manag-ement to the situation of power supply.
Static bypass has a strong anti-overload capacity.
Key Features:
1.Adopt full digital control technology
2.Intelligent detection and monitoring function
3.Digital control and static switch zero switching.
4.Input/output full isolation
5.DC UPS isolated with utility power completely.
6.Cubicle design with power standard.
7.Multifunctional protection for overvoltage,low voltage,
8.Overcurrent ,short circuit and so on.
9.Large-screen LCD monitor Chinese and English operation interface.
10.Ultralong 256 event records,user-friendly analysis and manag-ement
11.to the situation of power supply.
12.Static bypass has a strong anti-overload capacity.
Control System
Adopt microprocessor bus control technology and ensure the realtime control of rectifier,inverter,static switch as well as coordination of each power part,characterized by increased control of aging,higher reliability,
Improve the efficiency of complete UPS system.the output technical parameters are better than taht of the general capacity of equipment.
Model Power(kVA) | IPS9315C 10-120KVA | ||||||||
10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | |
Capacity | 9KW | 13.5KW | 18KW | 27KW | 36KW | 54KW | 72KW | 90KW | 108KW |
Input | |||||||||
Rated voltage | 380/400/415 Vac three-phase | ||||||||
Voltage range | ±20% | ||||||||
Frequency range | 50/60Hz±5% | ||||||||
Power factor | ≥0.9 | ||||||||
Current harmonic distortion | <5% wuth harmonic filter | ||||||||
Soft Start | 0-100% in 10′′ | ||||||||
Bypass Input | |||||||||
Rated voltage | 220/230/240Vac single-phase | ||||||||
Permitted voltage range | ±15%(selsetable from ±10% to±25% from front panel) | ||||||||
Rated frequency | 50/60Hz | ||||||||
permitted frequency range | ±2%(selectable from ±1% to ±5% from front panel) | ||||||||
Standard features | BackFeed portection;split bypass line | ||||||||
Batter | |||||||||
Type | Maintenance-free lead-acid VRLA AGM/GEL; | ||||||||
DC Voltage | 220/384VDC | ||||||||
AC ripple voltage | <1% | ||||||||
Inverter output | |||||||||
Rated voltage(V) | 220/230/240Vac single-phase | ||||||||
Regulation of theoutput voltage | 220/244Vac phase/neutral(from contril panel) | ||||||||
Crest factor(lpeak/irms) | 3:1 | ||||||||
static stability | ±1% | ||||||||
Dynamic stability | ±5% | ||||||||
Frequency | 50/60Hz configurable | ||||||||
Overload | 110% 125% 150% of the rated current for 1h/10′/1′ | ||||||||
Frequency stability | ±0.05% on mains failure | ||||||||
Remote signaling | Volt-free contacts | ||||||||
Remote controls | EPO and Bypass | ||||||||
Communication | RS232 + romote contacts | ||||||||
Operation temoerature | 0°C-40°C | ||||||||
Relative humidity | <95% non condensing | ||||||||
Colour | RAL7035 | ||||||||
Noise | 54dB at 1m | 60dB at 1m | 65dB at 1m | ||||||
Protection degree | IP42 | ||||||||
Effciency Smart Mode | UP to 94% | ||||||||
Compliance | Safety:EN 62040-1-1(Directive 2006/95/EC);EMC:6200-2(Directive 2004/108/EC) | ||||||||
Weight(KG)N.W | 200 | 220 | 230 | 290 | 340 | 440 | |||
Dimensions:(wxDxH)mm | 560*730*1220 | 800*850*1600 | 800*800*1900 | 1200*800*1900 | 1500*800*1900 | ||||
Internal batteries | Yes | Yes | Yes | No | No | No |